Overview
Display in surface mode
Menu
Select Menu with Set/Menu, then confirm with Enter
- Select the menu entry with Set/Menu
- Call selected entry with Enter
- Return to the previous screen with Exit
Menu/Logbook
Logbook
- Chronologically lists all dives in the profile memory (the most recent dive carries the number 1)
- Select dive with Set/Menu. Enter shows all details of the selected dive on a new page
graphical display of the dive
- Available information: date/time at the end of the dive, max. depth, dive time, min. temperature, air pressure before the dive in mbar, desaturation time in minutes after the dive, profile
- Back to the list with Set/Menu
Menu/Gas Setup
Gas Setup - Gaslist
Gas Setup Page 1
- Up to five gases can be configured (default is gas #1)
- Select with Set/Menu, increase single values with Enter
- Display of the current selection after the Gas number (e.g. 21/0)
- Reset the gas to compressed air with "Default"
- Configure shown gas as start gas with "First Gas?"
Gas Setup Page 2 / more
- On the second page, the gas can be (de-)activated
- The change depth can be specified
- Active gases are used to calculate the decompression
Menu/Reset all
Reset all
- Selection has to be confirmed with Enter for 10 s
- Gases, Custom Functions and decompression data will be reset to their standard values
- Logbook entry and time setting will not be deleted
Menu/Setup
- Calls a submenu "Setup menu"
Setup Menu
Menu/More
Menu 2
Menu/Setup/Custom Functions I
Custom Function I Example CF29
- 32 custom functions are individually configurable; custom functions (CF) are parameters that influence the running of the program
- Select the action with Set/Menu, confirm or change with Enter
- "+/-": increase or decrease value of the CF?
- "1/10": choose size of a step
- "Default": Resets CF to default values; the information in brackets shows whether it concerns a 8Bit number (0-255) or a 15Bit number (0-32767)
- "Current": applies the operation in question (e.g. "+10") to the current value
- CF0: water depth in cm for the automatic switch into dive mode
- CF1: water depth in cm for the automatic switch out of dive mode
- CF2: delay in s for end of dive mode
- CF3: timeout in s for menus and surface mode
- CF4: hold time in s for pre-menu display
- CF5: threshold in m/min for display of vertical velocity
- CF6: absolute pressure in mbar for switch-on from sleep mode
- CF7: max. "allowed" air pressure in mbar for air pressure compensation in sleep mode
- CF8: threshold in % for display of the gradient factor for decompression calculation
- CF9: Threshold in % (O2-Mix) for display of current gas in divemode
- CF10: timeout in s for menus in divemode
- CF11: factor in % for saturation processes
- CF12: factor in % for desaturation processes
- CF13: Ratio in % for NoFly-Time according to desaturation time
- CF14: Threshold in % for optical gradient factor alarm
- CF15: Threshold in % for acoustic gradient factor alarm
- CF16: estimated distance to decostop in 0.1m steps
- CF17: Lower threshold in 0.01Bar for ppO2 warning
- CF18: Upper threshold in 0.01Bar for ppO2 warning
- CF19: Upper threshold in 0.01Bar for ppO2 display in dive mode
- CF20: depth sampling rate in seconds for Profile storage
- CF21: sampling_divisor_temperature
- CF22: sampling_divisor_decodata
- CF23: sampling_divisor_tankdata
- CF24: sampling_divisor_ppo2_sensors
- CF25: sampling_divisor_nuy1 (Not used yet)
- CF26: sampling_divisor_nuy2 (Not used yet)
- CF27: threshold in % for display of the CNS value
- CF28: Logbook offset for detail view
- CF29: Depth of last Decostop
- CF30: delay in minutes for end of Apnoe mode
- CF31: show battery voltage or battery symbol
Red: Critical custom functions; if value is not set to default a warning will be displayed.
Menu/Setup/Custom Functions II
Custom Function II Example CF32
- CF32: GF low Value (GF Extension)
- CF33: GF high Value (GF Extension)
- CF34: HUD low ppO2 warning level (Only OSTC1)
- CF34: Color# battery (Only OSTC Mk.2)
- CF35: HUD high ppO2 warning level (Only OSTC1)
- CF35: Color# standard (Only OSTC Mk.2)
- CF36: HUD nominal ppO2 level (Only OSTC1)
- CF36: Color# Divemask (Only OSTC Mk.2)
- CF37: HUD Style (Only OSTC1)
- CF37: Color# Warnings (Only OSTC Mk.2)
- CF38: Show Seconds in Divetime
- CF39: Flip OLED vertically (Only OSTC1)
- CF40: Use Big ppO2 Output (Only OSTC1)
- CF41: Show Average Depth
- CF42: Blink Gas
- CF43: Depth warning (Color change) (Only OSTC Mk.2)
- CF44: CNS warning (Color change) (Only OSTC Mk.2)
- CF45: GF warning (Color change) (Only OSTC Mk.2)
- CF46: ppO2 warning (Color change) (Only OSTC Mk.2)
- CF47: Velocity warning (Color change) (Only OSTC Mk.2)
Red: Critical custom functions; if value is not set to default a warning will be displayed.
Menu/Setup/Internal Module (Only OSTC1)
- Configuration of a internal moduls
Internal Module
Menu/Setup/Decotype
- Switches between the different deco methods (ZH-L16 OC, Gauge, ZH-L16 CC, Apnoe, ZH-L16 GF OC and ZH-L16 GF CC)
- ZH-L16 OC: Bühlmann ZH-L16 for Open Circuit
- ZH-L16 CC: Bühlmann ZH-L16 for Closed Circuit (CCR and SCR)
- ZH-L16 GF OC: Bühlmann ZH-L16 for Open Circuit with GF Extension (Deep Stops)
- ZH-L16 GF CC: Bühlmann ZH-L16 for Closed Circuit (CCR and SCR) with GF Extension (Deep Stops)
- In Gauge or Apnoe mode, no decompression is calculated
- Apnoe temporally sets the depth sampling rate CF20 to one second
- The GF Extension was added in Firmware 1.19 and is still in a beta phase!
Menu/Setup/Debug
- Toggles the display of the debug informations (ON or OFF)
- In surface and divemode, 6 characters + "." are displayed
- new informations are added to the left and shift the older values to the right
- The last six routines that were executed can be checked
- If the divemode is interrupted with an interface-RESET a debug screen appears showing important informations - even if the debugmode was not set active!
- For example "rwxCBr.", Details here: Debug-Codes
Menu/More/Set Time
Set Time
- Manual setting of date and time
- Increase current value with Enter, select next one with Set/Menu. Seconds will be set to 0 after the last setting ("Set Year"), and the time will be shown for 5 seconds
The time can be set with just one mouseclick using "DivingLog" or "JdiveLog"
Menu/More/Const. ppO2 Setup
- Calls the menu for the ppO2 setup
Const. ppO2 Setup
- You can configure three "mixes", the diluent is the "First Gas" from the "Gas Setup"
- Current shows the current value
- Change + and Change - change the depth
- Default resets the mix
Menu/More/Battery Info
- Displays a battery informations page:
- Cycles counts the charge cycles (Value in brakets: complete cycles)
- Last Complete: Date of the last complete cycle
- Lowest VBatt: Lowest battery voltage seen
- Lowest at: Date of the lowest battery voltage
- Tmin: minimum temperature (in brakets: Date)
- Tmax: maximum temperature (in brakets: Date)
Menu/More/O2 Sensor Menu (Only OSTC1)
- Calls the external O2 sensor module menu
O2 Sensor Module
- Firmware Version of the external module
- ppO2 values of all three sensor plus meanvalue of all valid sensors
- voltage output of all sensors in millivolt [mV]
- entry to disable the module
- entry to calibrate the module
Menu/More/Simulator
- standalone simulator for diving mode presentation
Simulator Start
- Enter opens the depth change menu
Simulator at work