Overview


Display in surface mode

Menu

Select Menu with Set/Menu, then confirm with Enter
  • Select the menu entry with Set/Menu
  • Call selected entry with Enter
  • Return to the previous screen with Exit

Menu/Logbook


Logbook
  • Chronologically lists all dives in the profile memory (the most recent dive carries the number 1)
  • Select dive with Set/Menu. Enter shows all details of the selected dive on a new page

graphical display of the dive
  • Available information: date/time at the end of the dive, max. depth, dive time, min. temperature, air pressure before the dive in mbar, desaturation time in minutes after the dive, profile
  • Back to the list with Set/Menu

Menu/Gas Setup


Gas Setup - Gaslist

Gas Setup Page 1
  • Up to five gases can be configured (default is gas #1)
  • Select with Set/Menu, increase single values with Enter
  • Display of the current selection after the Gas number (e.g. 21/0)
  • Reset the gas to compressed air with "Default"
  • Configure shown gas as start gas with "First Gas?"

Gas Setup Page 2 / more
  • On the second page, the gas can be (de-)activated
  • The change depth can be specified
  • Active gases are used to calculate the decompression

Menu/Reset all


Reset all
  • Selection has to be confirmed with Enter for 10 s
  • Gases, Custom Functions and decompression data will be reset to their standard values
  • Logbook entry and time setting will not be deleted

Menu/Setup

  • Calls a submenu "Setup menu"

Setup Menu

Menu/More

  • Calls a submenu "Menu2"

Menu 2

Menu/Setup/Custom Functions I


Custom Function I Example CF29
  • 32 custom functions are individually configurable; custom functions (CF) are parameters that influence the running of the program
  • Select the action with Set/Menu, confirm or change with Enter
  • "+/-": increase or decrease value of the CF?
  • "1/10": choose size of a step
  • "Default": Resets CF to default values; the information in brackets shows whether it concerns a 8Bit number (0-255) or a 15Bit number (0-32767)
  • "Current": applies the operation in question (e.g. "+10") to the current value
  • CF0: water depth in cm for the automatic switch into dive mode
  • CF1: water depth in cm for the automatic switch out of dive mode
  • CF2: delay in s for end of dive mode
  • CF3: timeout in s for menus and surface mode
  • CF4: hold time in s for pre-menu display
  • CF5: threshold in m/min for display of vertical velocity
  • CF6: absolute pressure in mbar for switch-on from sleep mode
  • CF7: max. "allowed" air pressure in mbar for air pressure compensation in sleep mode
  • CF8: threshold in % for display of the gradient factor for decompression calculation
  • CF9: Threshold in % (O2-Mix) for display of current gas in divemode
  • CF10: timeout in s for menus in divemode
  • CF11: factor in % for saturation processes
  • CF12: factor in % for desaturation processes
  • CF13: Ratio in % for NoFly-Time according to desaturation time
  • CF14: Threshold in % for optical gradient factor alarm
  • CF15: Threshold in % for acoustic gradient factor alarm
  • CF16: estimated distance to decostop in 0.1m steps
  • CF17: Lower threshold in 0.01Bar for ppO2 warning
  • CF18: Upper threshold in 0.01Bar for ppO2 warning
  • CF19: Upper threshold in 0.01Bar for ppO2 display in dive mode
  • CF20: depth sampling rate in seconds for Profile storage
  • CF21: sampling_divisor_temperature
  • CF22: sampling_divisor_decodata
  • CF23: sampling_divisor_tankdata
  • CF24: sampling_divisor_ppo2_sensors
  • CF25: sampling_divisor_nuy1 (Not used yet)
  • CF26: sampling_divisor_nuy2 (Not used yet)
  • CF27: threshold in % for display of the CNS value
  • CF28: Logbook offset for detail view
  • CF29: Depth of last Decostop
  • CF30: delay in minutes for end of Apnoe mode
  • CF31: show battery voltage or battery symbol
Red: Critical custom functions; if value is not set to default a warning will be displayed.

Menu/Setup/Custom Functions II


Custom Function II Example CF32
  • CF32: GF low Value (GF Extension)
  • CF33: GF high Value (GF Extension)
  • CF34: HUD low ppO2 warning level (Only OSTC1)
  • CF34: Color# battery (Only OSTC Mk.2)
  • CF35: HUD high ppO2 warning level (Only OSTC1)
  • CF35: Color# standard (Only OSTC Mk.2)
  • CF36: HUD nominal ppO2 level (Only OSTC1)
  • CF36: Color# Divemask (Only OSTC Mk.2)
  • CF37: HUD Style (Only OSTC1)
  • CF37: Color# Warnings (Only OSTC Mk.2)
  • CF38: Show Seconds in Divetime
  • CF39: Flip OLED vertically (Only OSTC1)
  • CF40: Use Big ppO2 Output (Only OSTC1)
  • CF41: Show Average Depth
  • CF42: Blink Gas
  • CF43: Depth warning (Color change) (Only OSTC Mk.2)
  • CF44: CNS warning (Color change) (Only OSTC Mk.2)
  • CF45: GF warning (Color change) (Only OSTC Mk.2)
  • CF46: ppO2 warning (Color change) (Only OSTC Mk.2)
  • CF47: Velocity warning (Color change) (Only OSTC Mk.2)
Red: Critical custom functions; if value is not set to default a warning will be displayed.

Menu/Setup/Internal Module (Only OSTC1)

  • Configuration of a internal moduls

Internal Module

Menu/Setup/Decotype

  • Switches between the different deco methods (ZH-L16 OC, Gauge, ZH-L16 CC, Apnoe, ZH-L16 GF OC and ZH-L16 GF CC)
  • ZH-L16 OC: Bühlmann ZH-L16 for Open Circuit
  • ZH-L16 CC: Bühlmann ZH-L16 for Closed Circuit (CCR and SCR)
  • ZH-L16 GF OC: Bühlmann ZH-L16 for Open Circuit with GF Extension (Deep Stops)
  • ZH-L16 GF CC: Bühlmann ZH-L16 for Closed Circuit (CCR and SCR) with GF Extension (Deep Stops)
  • In Gauge or Apnoe mode, no decompression is calculated
  • Apnoe temporally sets the depth sampling rate CF20 to one second
  • The GF Extension was added in Firmware 1.19 and is still in a beta phase!

Menu/Setup/Debug

  • Toggles the display of the debug informations (ON or OFF)
  • In surface and divemode, 6 characters + "." are displayed
  • new informations are added to the left and shift the older values to the right
  • The last six routines that were executed can be checked
  • If the divemode is interrupted with an interface-RESET a debug screen appears showing important informations - even if the debugmode was not set active!
  • For example "rwxCBr.", Details here: Debug-Codes

Menu/More/Set Time


Set Time
  • Manual setting of date and time
  • Increase current value with Enter, select next one with Set/Menu. Seconds will be set to 0 after the last setting ("Set Year"), and the time will be shown for 5 seconds

The time can be set with just one mouseclick using "DivingLog" or "JdiveLog"

Menu/More/Const. ppO2 Setup

  • Calls the menu for the ppO2 setup

Const. ppO2 Setup
  • You can configure three "mixes", the diluent is the "First Gas" from the "Gas Setup"
  • Current shows the current value
  • Change + and Change - change the depth
  • Default resets the mix

Menu/More/Battery Info

  • Displays a battery informations page:
  • Cycles counts the charge cycles (Value in brakets: complete cycles)
  • Last Complete: Date of the last complete cycle
  • Lowest VBatt: Lowest battery voltage seen
  • Lowest at: Date of the lowest battery voltage
  • Tmin: minimum temperature (in brakets: Date)
  • Tmax: maximum temperature (in brakets: Date)

Menu/More/O2 Sensor Menu (Only OSTC1)

  • Calls the external O2 sensor module menu

O2 Sensor Module
  • Firmware Version of the external module
  • ppO2 values of all three sensor plus meanvalue of all valid sensors
  • voltage output of all sensors in millivolt [mV]
  • entry to disable the module
  • entry to calibrate the module

Menu/More/Simulator

  • standalone simulator for diving mode presentation

Simulator Start
  • Enter opens the depth change menu

Simulator at work