CF23:Tank data sampling divisor

This value sets how often the tank data (dependent on the sampling rate CF20) should be stored in the dive profile.

Recommend range:

  • 2 ... 10 (Every 2...10 depth samples, the tank data is stored additionally)

Default setting:

  • 0 (The tank data is not stored)

Example 1: CF20=10 CF23 = 2

  • Every ten seconds, the depth is stored. The tank data is stored every 20 seconds additionally

Example 2: CF20=1 CF23 = 60

  • Every second, the depth is stored. The tank data is stored every minute additionally

Example 3: CF23 = 0

  • The tank data is not stored as all.