Recent Changes - Search:

OSTC

DR5

PmWiki

CF12

CF12:factor in % for desaturation processes

With this value (factor in Percent) the desaturation processes are shifted. A value below 100 (100%) means that less N2 and He desaturation is calculated then designated from Bühlmann. This results in a slower desaturation between the dives.

Values above 100 (100%) mean that more desaturation is calculated (faster desaturation). This is only recommend when experimenting with the simulator but not for real-dive use!

Default setting:

  • 90 (90%)

Example: CF12=90

  • The desaturaion is slower then designated from Bühlmann.

This is critical custom function! If the value is above 90 a warning symbol (Skull) is displayed permanently during Surface- and Divemode. Do NOT dive with a OSTC configured that way!

Back to: CF11

Continue with: CF13

Edit - History - Print - Recent Changes - Search
Page last modified on November 06, 2008, at 03:41 AM EST