Overview surface mode:

Overview dive mode:

Short manual for OSTC:
 |
Display in surface mode |
Turn-on procedure:
- Manual turn-on: Keep both buttons on hold for two seconds
- Automatic turn-on: The OSTC switches itself on after 5 seconds (at
the latest) in about 2,5 m water depth
Turn-off procedure:
The OSTC switches automatically into sleep mode after 240 s in surface
mode (CF #3 in s)
Menu:
| |
Press Set/Menu, confirm with Enter
|
Logbook:
|
|


|
- Chronologically lists all dives in the profile memory
(the most recent dive carries the number 1)
- Select dive with Set/Menu. Enter shows
all details of the selected dive on a new page
- Available information:
date/time at the end of the dive, max. depth, dive time,
min. temperature, air pressure before the dive in mbar,
max. allowed altitude in m directly after the dive, profile
- Back to the list with Set/Menu
|
Gas Setup: |
|
| |
- Up to five gases can be configured (default is gas #1)
- Select with Set/Menu, increase single values
with Enter
- Display of the current selection under "Current"
- Reset the gas to compressed air with "Default"
|
Set Time:
|
|

|
- Manual setting of date and time
- Increase current value with Enter, select next
one with Set/Menu. Seconds will be set to 0 after
the last setting ("Set Year"), and the time will be shown
for 5 seconds
|
Reset all: |
|
| |
Selection has to be confirmed with Enter for 10s, then
gases, Custom Functions and decompression data will be reset
to their standard values. Logbook and time will not be deleted.
|
Custom Functions: |
|
| |
- 32 custom functions are individually configurable; custom
functions (CF) are parameters that influence the running of
the program
- Select the action with Set/Menu, confirm or change
with Enter
- "+/-": increase or decrease value of the CF?
- "1/10": choose size of a step
- "Default": Resets CF to default values; the information in
brackets shows whether it concerns a 8Bit number (0-255) or
a 15Bit number (0-32767)
- "Current": applies the operation in question (e.g. "+10")
to the current value
- CF0: water depth in cm for the automatic switch into dive
mode
- CF1: water depth in cm for the automatic switch out of
dive mode
- CF2: delay in s for end of dive mode
- CF3: timeout in s for menus and surface mode
- CF4: hold time in s for pre-menu display
- CF5: threshold in m/min for display of vertical velocity
- CF6: absolute pressure in mbar for switch-on from sleep
mode
- CF7: max. "allowed" air pressure in mbar for air pressure
compensation in sleep mode
- CF8: threshold in % for display of the gradient factor
for decompression calculation
- CF9: Threshold in % (O2-Mix) for display of current gas
in divemode
- CF10: timeout in s for menus in divemode
- CF11: factor in % for saturation processes *
- CF12: factor in % for desaturation processes *
- CF13: Ratio in % for NoFly-Time according to desaturation
time
- CF14: Treshold in % for optical gradient factor alarm
- CF15: Treshold in % for acustic gradient factor alarm
- CF16: estimated distance to decostop in 0.1m steps
- CF17: Lower treshold in 0.01Bar for ppO2 warning *
- CF18: Upper treshold in 0.01Bar for ppO2 warning *
- CF19: Upper treshold in 0.01Bar for ppO2 display in dive
mode *
- CF20: depth sampling rate in seconds for Profile storage
- CF21: sampling_divisor_temperature (For details see PDF
file "Protocol description" in Downloads)
- CF22: sampling_divisor_decodata (For details see PDF file
"Protocol description" in Downloads)
- CF23: sampling_divisor_tankdata (For details see PDF file
"Protocol description" in Downloads)
- CF24: sampling_divisor_ppo2_sensors (For details see PDF
file "Protocol description" in Downloads)
- CF25: sampling_divisor_nyu1 (Not used yet) (For details
see PDF file "Protocol description" in Downloads)
- CF26: sampling_divisor_nyu2 (Not used yet) (For details
see PDF file "Protocol description" in Downloads)
* Critical custom functions! If
value is not set to default a warning will be displayed! |
| |
Dive mode:
| |
Display in dive mode
|
 |
Menu in dive mode |
|
|